Harmonic filter DHL


产品编号:

1133004284338262016

DHL series harmonic filter products are used to filter one or more current harmonics in the power grid side system.

所属分类:

Reactor series

  • Product description
  • Product features
  • Technical specifications
  • Product size
  • DHL series harmonic filter products are used to filter one or more current harmonics in the power grid side system.
    1. Compared with traditional passive filters, DHL series products have smaller volume and stronger harmonic suppression capability.
    2. When connected to the front end of the frequency converter, the total harmonic current filtered by the harmonic filter is less than 10% of the fundamental current at full load.
    3. The efficiency is more than 98%, and the power can reach 250KW. The passive harmonic filter provides a stable and reliable harmonic solution with high cost performance.
    4. As an independent option, it is easy to install into the existing cabinet.
    5. This series of filters has been carefully matched with the brand frequency converter, which is suitable for a variety of motor control methods to ensure the stable operation of the system without any adverse impact on the power grid.
    6. It can be directly used together with the DC reactance and EMC/EMI filter that have been installed previously.

  • Product characteristics

    1. Rated working voltage: AC380V~480V
    2. Frequency: 50Hz
    3. Overload capacity: 1.6 times, 60s
    4. Absolute level: overvoltage category III in accordance with EN61800-5-1
    5. Full load efficiency: more than 98%
    6. Cooling mode: AN
    7. Harmonic filtering effect: under full load condition, the total harmonic current distortion rate (THID) of the filter input is less than 10% (background voltage THUD is less than 2%, and the ratio of power grid short circuit power to installed load is more than 66)
    8. Ambient temperature (working): - 25 ℃~+50 ℃ under full load
    9. Storage temperature: - 25 ℃~ 65 ℃
    10. Working altitude: 0~2000m above sea level
    11. Relative humidity: 0~95% without condensation
    12. No load current: less than 25% of rated current
    13. Applicable standard: IEC60076; GB19212.1-2008;  GB19212.21-2007;  GB1094.6-2011

     

    Precautions

    1. DHL harmonic filter is the filter matched with frequency converter, which can only be installed at the power inlet of uncontrolled rectifier frequency converter;
    2. When selecting, the power of the filter should match the power of the inverter as much as possible, so that better filtering effect can be obtained. If the filter with larger power is used for the inverter with smaller power, the filtering effect will be reduced;
    3. The reactor in the filter is a heating device. During installation, pay attention to keeping at least 100mm space around the filter;
    4. During installation, connect reliable ground wires according to the wiring instructions in the circuit diagram
    5. Please consult the manufacturer when the use environment such as altitude and power grid quality exceeds the technical requirements

     

    Product ldentification Code

    DHL  —  0300K  —  EISA  —  04
         

    Product Type 

     

    Power

     

    Structure and Material

     

    Inductance

    400V

     

  • Product Application

    1. Equipment equipped with front-end six pulse rectifier
    2. AC and DC motor drives
    3. Factory automation equipment
    4. UPS and three-phase power supply
    5. Water/Wastewater Treatment Facilities
    6. Oil and gas exploration
    7. Heavy industry and machinery
    8. Self contained system (such as ship)
    9. Fan and pump application
    10. Battery charger
    11. Heating, ventilation and air conditioning engineering devices
    12. Key works

  •  

    Product model Drawing No Adaptive power (KW) Rated current (A) Size Dimension(±2mm) Weight(KG±10%)
    L W H D1 D2 W1 A*B
    DHL-2.2K-04-10 A 2.2 5.6 445 245 245 392 345 216 9*13.5 40Kg
    DHL-3K-04-10 3 7.2 445 245 245 392 345 216 9*13.5 40Kg
    DHL-5.5K-04-10 5.5 12.6 480 285 245 432 385 256 9*13.5 40Kg
    DHL-7.5K-04-10 7.5 17 480 285 245 432 385 256 9*13.5 40Kg
    DHL-11K-04-10 11 25 555 340 310 503 439 311 11*16.5 45Kg
    DHL-15K-04-10 15 32 555 340 310 503 439 311 11*16.5 50Kg
    DHL-18.5K-04-10 18.5 38 555 340 310 503 439 311 11*16.5 50Kg
    DHL-22K-04-10 22 45 600 400 330 543 479 372 11*16.5 58Kg
    DHL-30K-04-10 30 61 600 400 330 543 479 372 11*16.5 58Kg
    DHL-37K-04-10 37 72 600 400 330 543 479 372 11*16.5 58Kg
    DHL-45K-04-10 B 45 88 665 420 360 596 550 392 11*16.5 80Kg
    DHL-55K-04-10 55 105 665 420 360 596 550 392 11*16.5 80Kg
    DHL-75K-04-10 75 145 780 450 400 687 619 420 11*16.5 140Kg
    DHL-90K-04-10 90 169 780 450 400 687 619 420 11*16.5 140Kg
    DHL-110K-04-10 110 206 860 510 435 766 708 485 11*17.5 140Kg
    DHL-132K-04-10 132 246 860 510 435 766 708 485 11*17.5 140Kg
    DHL-160K-04-10 160 293 830 515 445 766 708 488 11*17.5 185Kg
    DHL-200K-04-10 C 200 363 1035 510 435 946 886 485 11*20 220Kg
    DHL-250K-04-10 250 430 1035 510 435 946 886 485 11*20 230Kg

DHL series harmonic filter products are used to filter one or more current harmonics in the power grid side system.
1. Compared with traditional passive filters, DHL series products have smaller volume and stronger harmonic suppression capability.
2. When connected to the front end of the frequency converter, the total harmonic current filtered by the harmonic filter is less than 10% of the fundamental current at full load.
3. The efficiency is more than 98%, and the power can reach 250KW. The passive harmonic filter provides a stable and reliable harmonic solution with high cost performance.
4. As an independent option, it is easy to install into the existing cabinet.
5. This series of filters has been carefully matched with the brand frequency converter, which is suitable for a variety of motor control methods to ensure the stable operation of the system without any adverse impact on the power grid.
6. It can be directly used together with the DC reactance and EMC/EMI filter that have been installed previously.