PRODUCT CENTER

Famous Operators of Integrated Solutions in Power Electronics

PRODUCT

product center

Three phase input reactor ASL
Number of views:
1000

Three phase input reactor ASL

The three-phase input reactor is installed on the input side of the frequency converter to protect the frequency converter from transient overvoltage.
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number:
Category:
Reactor series
Quantity
-
+
Stock:
1
Product description
Parameters
Product features
Technical specifications
Product size

ASL series three-phase input reactor products are installed on the input side of the frequency converter to protect the frequency converter from the impact of transient overvoltage. It can reduce the surge and peak current, improve the real power factor of the power supply, suppress the harmonic of the power grid, and improve the waveform of the input current.
1. The power supply has obvious interference (interference, overvoltage) to other equipment
2. Unbalanced voltage between power supply phases>1.8% of rated voltage
3. Lines with extremely low impedance (the power transformer is more than 10 times of the rated value of the frequency converter)
4. A large number of frequency converters installed on one line to reduce line current
5. Use cos ф (Power factor) correction capacitor or power factor correction unit

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Product characteristics

1. Rated working voltage: 220VAC-1140VAC 50/60Hz
2. Rated working current: 5A to 1600A @ 40 ℃;
3. Dielectric strength: core winding 3000VAC/50Hz/5mA/10s without flying fox breakdown (factory test)
4. Insulation resistance: core winding 1000VDC insulation resistance ≥ 100M Ω
5. Reactor noise: less than 80dB (measured at 1m from the reactor)
6. Protection grade: IP00
7. Insulation grade: above F
8. Maximum current: 1.5 * rated current, lasting for 60s
9. Temperature rise: ≤ 85K
10. Applicable standard: IEC60076; GB19212.1-2008;  GB19212.21-2007;  GB1094.6-2011

 

Environmental conditions

1. The altitude does not exceed 2000 meters
2. Temperature resistance class F (155 ℃) or above
3. The operating ambient temperature is - 25 ℃~+45 ℃, and the relative humidity is not more than 90%

 

Product ldentification Code

ASL  —  0200  —  EISA  —  E7OU
        

Product Type

 

Current

 

Structure and Material

 

Inductance

 

Product Application

In particular, it is recommended to use input reactors in the following environments:
1. Several inverters are closely connected in parallel
2. The line power supply has obvious disturbance (interference, overvoltage) from other equipment;
3. The voltage between each phase of the line power supply is unbalanced, exceeding 1.8% of the rated voltage
4. A large number of frequency converters are installed on the same line
5. Reduce cos ф Correct the overload on the capacitor if the device contains a power factor correction device
6. The power supply capacity is 60KVA and above, and the frequency converter is installed within 10M from the large capacity power supply
7. The frequency converter is powered by lines with very low impedance (when the capacity of the frequency converter is 10 times higher than the rated value of the frequency converter)

Product Size

380V 2% Product size

Product model Drawing No Adaptive power(KW) Rated current (A) Inductance (mH) Pressure drop Insulation class

Size

Dimension(±2mm)

Weight(KG±10%)
L W H D W1 A*B
ASL-0005-EISA-E2M8 A 1.5 5 2.8 2% F.H 120 75 135 90 52 6*12 2.5
ASL-0007-EISA-E2M0 2.2 7 2 2% F.H 120 75 135 90 52 6*12 2.5
ASL-0010-EISA-E1M4 3.7 10 1.4 2% F.H 120 75 135 90 52 6*12 2.9
ASL-0015-EISA-EM94 5.5 15 0.94 2% F.H 120 75 135 90 52 6*12 2.9
ASL-0020-EISA-EM70 7.5 20 0.7 2% F.H 120 75 135 90 52 6*12 3.0
ASL-0030-EISA-EM47 B 11 30 0.47 2% F.H 155 140 140 95 61 6*12 5.0
ASL-0040-EISA-EM36 15 40 0.36 2% F.H 155 140 140 95 61 6*12 5.0
ASL-0050-EISA-EM28 18.5 50 0.28 2% F.H 180 155 165 120 80 8.5*20 8.0
ASL-0060-EISA-EM24 22 60 0.24 2% F.H 180 155 165 120 80 8.5*20 8.0
ASL-0080-EISA-EM18 30 80 0.18 2% F.H 180 155 165 120 80 8.5*20 8.0
ASL-0090-EISA-EM16 37 90 0.156 2% F.H 180 155 165 120 80 8.5*20 8.0
ASL-0120-EISA-EM12 45 120 0.117 2% F.H 195 185 195 120 98 8.5*20 13.0
ASL-0150-EISA-E94U 55 150 0.094 2% F.H 195 185 195 120 98 8.5*20 13.0
ASL-0200-EISA-E70U C 75 200 0.07 2% F.H 245 175 255 182 98 11*18 23.0
ASL-0250-EISA-E56U 110 250 0.056 2% F.H 245 175 255 182 98 11*18 23.0
ASL-0290-EISA-E48U 132 290 0.048 2% F.H 245 175 255 182 98 11*18 23.0
ASL-0330-EISA-E42U 160 330 0.042 2% F.H 295 190 275 214 104 12*20 36.0
ASL-0390-EISA-E36U 185 390 0.036 2% F.H 295 190 275 214 104 12*20 36.0
ASL-0490-EISA-E28U 220 490 0.028 2% F.H 295 190 275 214 104 12*20 36.0
ASL-0600-EISA-E24U 280 600 0.024 2% F.H 295 220 295 214 114 12*20 40.0
ASL-0660-EISA-E22U 300 660 0.022 2% F.H 295 220 295 214 114 12*20 40.0
ASL-0800-EISA-E18U 380 800 0.0175 2% F.H 345 235 315 270 129 12*20 52.0
ASL-1000-EISA-E14U 450 1000 0.014 2% F.H 380 255 345 290 129 12*20 58.0
ASL-1200-EISA-E12U D 550 1200 0.0117 2% F.H 380 260 425 290 134 12*20 75.0
ASL-1600-EISA-E8U6 630 1600 0.0086 2% F.H 380 290 425 290 159 12*20 90.0

690V 2% Product size

Product model Drawing No Adaptive power (KW) Rated current (A) Inductance (mH) pressure drop Insulation class Size(±1mm) Weight(KG±10%)
L W H D W1 A*B
ASL-0005-EISA-E5M6 A 3.7 5 5.6 2% F.H 120 75 135 90 52 6*12 3.0
ASL-0007-EISA-E4M0 5.5 7 4 2% F.H 120 75 135 90 52 6*12 3.0
ASL-0010-EISA-E2M8 7.5 10 2.8 2% F.H 155 90 165 95 61 6*12 5.6
ASL-0015-EISA-E1M9 11 15 1.87 2% F.H 155 90 165 95 61 6*12 5.6
ASL-0020-EISA-E1M4 15/18.5 20 1.4 2% F.H 155 90 165 95 61 6*12 5.6
ASL-0030-EISA-EM93 B 22 30 0.93 2% F.H 180 90 165 120 83 8.5*10 8.0
ASL-0040-EISA-EM70 30 40 0.7 2% F.H 180 155 165 120 83 8.5*20 8.0
ASL-0050-EISA-EM56 37/45 50 0.56 2% F.H 190 175 165 120 98 8.5*20 10.0
ASL-0060-EISA-EM47 55 60 0.47 2% F.H 190 175 165 120 98 8.5*20 10.0
ASL-0080-EISA-EM35 75 80 0.35 2% F.H 220 175 205 150 96 11*18 15.0
ASL-0090-EISA-EM31 90 90 0.31 2% F.H 220 175 205 150 96 11*18 15.0
ASL-0120-EISA-EM23 C 110 120 0.23 2% F.H 245 195 225 182 118 11*18 25.0
ASL-0150-EISA-EM19 110 120 0.19 2% F.H 245 195 225 182 118 11*18 25.0
ASL-0200-EISA-EM14 160/185 200 0.14 2% F.H 295 205 275 214 124 12*20 36.0
ASL-0250-EISA-EM11 220 250 0.11 2% F.H 295 205 275 214 124 12*20 36.0
ASL-0290-EISA-E96U 240 290 0.096 2% F.H 295 205 275 214 124 12*20 36.0
ASL-0330-EISA-E85U 280/300 330 0.085 2% F.H 295 265 275 214 154 12*20 50.0
ASL-0390-EISA-E72U 380 390 0.072 2% F.H 295 265 275 214 154 12*20 50.0
ASL-0490-EISA-E57U 450 490 0.057 2% F.H 295 265 275 214 154 12*20 50.0
ASL-0600-EISA-E47U D 550 600 0.047 2% F.H 380 265 320 290 164 12*20 74.0
ASL-0660-EISA-E42U 630 660 0.042 2% F.H 380 265 320 290 164 12*20 74.0
ASL-0800-EISA-E35U 710 800 0.035 2% F.H 380 295 350 290 174 12*20 85.0
ASL-1000-EISA-E28U 800 1000 0.028 2% F.H 380 310 350 290 194 12*20 105.0

 